CONCENTRATED WATER REPELLENT ADDITIVE

Innovative product improves the performance of all silicates, makes treated substrates water-repellent with a pearling effect.

yellow bar
HG120WPWP is a concentrated, colorless HYDROPHOBIC agent in aqueous emulsion, capable of developing a high water-repellent performance of concrete surfaces and absorbent mineral building materials.

Added at 10% in silicates / consolidants

Lithium or Sodium / Potassium base, in addition to the benefits they carry out, makes the treated supports water-repellent with a pearling effect. Particularly suitable for the "Concrete Hardener" line:
  • Concrete Hardener H10 - H35
  • Concrete Hardener Lithium
  • Concrete Hardener Lithium Pro

Added at 10%

To implement the performance in common water-based alkaline sealants for anti-dust treatments of cementitious substrates. Used on internal, external, new or existing concrete or cement surfaces that need to implement impermeability to liquids, without altering their breathability, offering a stable aesthetic degree.

As a direct water repellent

If diluted 5-10% in water alone, it is an excellent water repellent and hydrophobic protective agent for all absorbent cement, stone and brick materials exposed to the action of water:
  • Cementitious plasters
  • Prefabricated panels or exposed concrete blocks
  • Limestone and natural stones in general
  • Exposed bricks and tuff
  • Suitable for dispersion paints and varnishes.
yellow bar

Strengths

Compatible with all water based systems.

It provides water repellency to organic and inorganic alkaline water-based products.

It does not create a film and does not compromise the breathability of the substrate.

It reduces the absorption of liquid water (better impermeability) without altering the passage of water vapor.

Greater resistance to chemical aggression, to salts and pollutants dissolved in water and to stains, reducing the grip of dirt.

Decreases the risk of aggregate alkali reactions (ASR).

Prevents the formation of efflorescence from rising damp.

Improves resistance to vegetable and mineral oil stains.

HG120 WP Application

yellow bar
HG120WP AS ADDITIVE TO Concrete HARDENER H10:
Shake HG120WP before use and add it under mixing in the measure of 10% to the ready-to-use silicate “Concrete Hardener H10”.
HG120WP AS ADDITIVE TO Concrete HARDENER H35:
Dilute Concrete Hardener H35 with water in the respective ratio of 1: 2. Shake HG120WP before use and add it under mixing in the measure of 10% to the diluted “Concrete Hardener H35” silicate.
HG120WP AS ADDITIVE TO Concrete HARDENER LITHIUM:
Shake before use and add it to the Concrete Hardener Lithium while mixing, in the measure of 10%.
PROPERTIES OF MODIFIED HARDENER H10-H35-LITHIUM Concrete:
By adding HG120WP to the Concrete Hardener, you get a permanent, water-based, transparent and odorless CONSOLIDATING, HARDENING, WATER-REPELLENT protective for concrete and cement-based surfaces in general.
This particular molecule, penetrating into the support, chemically reacts to form a transpiring seal of the capillaries, making the cement structure harder, more resistant to wear, less absorbent to liquids, water repellent, ultimately brings the support to its maximum useful life.
The concrete improves considerably, both in terms of appearance and technical characteristics, by means of the surface treatment with MODIFIED Concrete HARDENER. This penetrates into the porosities of the cement, chemically reacts with the Ca (OH) 2 present therein, forming a calcium silicate gel (CSH).
The impregnation of the pores, in addition to improving the aesthetics, drastically reduces the permeability to water, but not to steam, increasing the surface hardness, the durability of the concrete and in particular the resistance to acid attack. By allowing moisture to escape, you avoid the risk of frost.

IMPREGNATION OF CONCRETE FLOORS, INTERIOR SURFACES, EXTERIOR CONCRETE OR CEMENT

The Concrete HARDENER penetrates into the porosity of the cement and, from the first application, completely invades all the porosities, including capillaries, reacting with the ions present in the hardened cement, forming a calcium silicate gel resistant and impervious to water and other liquids, according to the reaction: Ca ++ + SinO2n + 1> CaO ∙ SinO2n + 1. This reaction takes place inside the pores of the cement. The formed Casilicato gel obstructs porosities, making the concrete impermeable to liquids and at the same time harder, more resistant to wear, insensitive to carbonation and more resistant to the aggressive action of chlorides.
The use of the Lithium version, in contact with metals, forms monomolecular films of metal silicates, impervious to oxygen and acids and therefore acts as an anticorrosive. In order to provide maximum performance to the concrete flooring, we recommend the use of the modified Lithium version, which is able to penetrate the capillary porosities of the concrete thanks to its low viscosity and above all low surface tension and in this it is distinguished from others. similar products available on the market. Thanks to its characteristics, Concrete HARDENER LITHIUM + HG120WP penetrates deeper and allows excellent waterproofing to be achieved.

FIELDS OF USE:

Incorporated treatment for impregnation of concrete floors, internal, external, new or existing concrete or cement surfaces that need to implement EXTREMELY resistance to abrasion and hardness, impermeability to liquids, not altering their breathability, offering a stable aesthetic degree.
Particularly suitable for high density concrete.

HG120 WP THE ADVANTAGES

yellow bar
Floors treated with Concrete Hardener + HG120WP acquire: water repellency, greater hardness, superior scratch resistance, high resistance to chemical agents, anti-allergic surface, high brilliance.
  • Deep impregnation, thanks to a low surface tension.
  • It reduces the absorption of liquid water (better impermeability) without altering the passage of water vapor.
  • Greater resistance to chemical aggressions, stains and dirt pick-up.
  • Very useful for protecting the surface from tire marks or forklift-type rubber wheels.
  • Decreases the risk of aggregate alkali reactions (ASR)
  • Prevents the formation of efflorescence, mold and moisture rising fungi.
  • Protects from contamination of mineral and vegetable oils.
  • Protects from penetration and aggression of chloride ions.
  • By acting on internal cohesion of concrete, increases compressive strength and abrasion.
  • In the case of colo treatmentrant of the concrete with Concrete Color Dye, protects the color applied by light intensifyingmind tonality and lucidity.
  • Restarting the area, after a few hours from the treatmentbut bearing in mind that the reaction is completed by 2 weeks.
yellow bar

AFTER ADDING HG120WP TO THE CONCRETE HARDENER, PROCEED AS FOLLOWS:

the surfaces suitable for receiving the treatment must be cohesive, free of dust, clean and dry, free of polluting substances that could compromise the absorption in part or in total of the product. During sanding cycles or on smooth surfaces (with a low profile of roughness), use low pressure nebulizers, spray the product and distribute it evenly with a microfibre cloth, while on surfaces with a rough profile such as brushed concrete, use industrial brushes.
After applying as a consolidant, wait 6-12 hours to continue the sanding cycle. The product must not dry before it has penetrated deeply. If the absorption of the liquid is slow, moderately humidify the treated surface with occasional sprays of water, without exaggerating so as not to excessively dilute the
impregnating solution. While, if the absorption is immediate, adjust the quantity in order to keep the product moist for at least 30 minutes.
The treatment as a densifier can be performed on freshly cast concrete, after trowelling or smoothing, 12-24-48 hours after the first application, if the treated surface is still absorbent, reapply the modified Concrete Hardener until the pores are saturated. Remove any non-absorbed liquid and let the surface dry.
After 3 days from the 1st application, you can
wet the surface with water and check its waterproofing. In very old cements the calcium present is almost all insoluble and therefore unable to generate Ca ++. In this case, a preliminary treatment with a 5% solution of calcium nitrate or calcium acetate is required.

HG120WP AS A HYDROPHOBE DIRECTLY DILUTED IN WATER:

The product is supplied in concentrated form and must be diluted with water at the time of application, to the extent that varies from 5 to 10%. If long storage times of the diluted product are expected, use distilled water.
Apply with low pressure manual sprayers (0.5 bar) on cohesive surfaces, free of dust, clean and dry, free of polluting substances that could compromise the absorption in part or total of the product. For applications on façades, in order to avoid excessive consumption and risks of toning, it is recommended to lay them when the wall is in the shade.
The effectiveness of the water-repellent treatment with diluted HG120WP will depend on the absorbency of the substrate together with the amount of product applied. The consumption of the diluted product (HG120WP diluted 10% in water) on concrete and brick substrates can vary from 0,250 to 0,500 kg / m2 (25-50 gr / m2 of HG120WP Concentrate). For consumption on stone supports, it is advisable to carry out a test to check for any toning of the mineral type).
yellow bar

HG120WP

Consolidating + 10% HG120WP

IMPORTANT NOTICES:

For applications on bricks and terracotta, slight toning of the material may occur, it is therefore advisable to carry out a test in the conditions of the construction site.
The instructions given in this sheet are indicative of an average case history and do not replace the evaluation of the professional user who will have to decide the choice of the right product and its best application in relation to the specific case he is facing.
Before each application, carry out a compatibility test of the product for the required use, for the materials and for the environment for which it is intended, in relation to one's own professional and personal, environmental and general conditions in which it must operate. The supplier, not being present at the time of application, is not liable for damages of any kind, direct or indirect to people, things, the environment, activities or work in progress, resulting from the choice and application of the product. as these constitute a free and conscious professional choice of the user.